  • Designed to use with bathroom or kitchen exhaust venting systems
  • Quality constructed in 28 gauge Galvanized steel
  • Comes with a damper to prevent back draft and with an insect screen

Estimated Delivery:

Sep-25  -  Oct-02
Free Shipping

Free Shipping

This product qualifies for free shipping.

Ready to Ship

Ready to Ship

Typically ships between 1-2 business days.

RDP Goose Neck Exhaust Roof Vent

$62.45$199.45

Item# RDP-GN

(15 customer reviews)

Product Summary

The RDP Goose Neck Exhaust Roof Vent is designed to use with bathroom or kitchen exhaust venting systems. This roof mounted vent comes with a damper to prevent back draft and with an insect screen, and with a 3″ stem for flex pipe connections. Quality constructed in 28 gauge Galvanized steel. The RDP Goose Neck Exhaust Roof Vent comes in the following sizes: 4 inch, 5 inch, 6 inch, 8 inch and 10 inch. This model does not come with an extension. This product is also available with the bottom extension here. This vent is not intended for roof top dryer termination.

RoofingDirect.com offers an excellent selection of exhaust vents made of high quality materials for your next job. Our team has decades of industry experience and is ready to serve you. Please contact us, and we will be happy to answer any questions.

Features + Benefits

  • Designed to use with bathroom or kitchen exhaust venting systems
  • Quality constructed in 28 gauge Galvanized steel
  • Comes with a damper to prevent back draft and with an insect screen

Product Specifications

Item #
RDP-GN
Brand
Weight
3 lbs
Material
28 Gauge Galvanized Steel

Warranty & Documents

Product Reviews

4.7 of 5.0 Stars
(15 Reviews)
4.67/5

15 reviews for RDP Goose Neck Exhaust Roof Vent

  1. Scott Jonello (verified customer)

    Great sturdy product would recommend this company to family and friends

    • AM (store manager)

      Hi Scott, Thanks for the great feedback. We appreciate that as we are a family owned company. We appreciate your business.

  2. David Harness (verified customer)

    Product arrived quickly and was well packaged. I didn’t receive any shipping confirmation or arrival date. Would have been nice to plan install.

    • AM (store manager)

      Hi David, we apologize you did not receive the order confirmation or tracking emails. These are automatically generated and sometimes can end up in spam folders. Thanks again for the order, we appreciate your business.

  3. Michael Bailey (verified customer)

    Quick delivery and exact product I needed

    • CL (store manager)

      Sounds like a perfect match. Thanks for shopping at roofing direct!

  4. Aaron M. (verified customer)

    Well built, looks good. The right product for our new 900 cfm kitchen hood with 8 inch vent pipe.

    • CL (store manager)

      Thanks for reviewing the Goose Neck Exhaust Vent!

  5. Reginaldo Peixe (verified customer)

    • Daysia W (store manager)

      Hi Reginaldo! Thanks for taking the time to review the Goose Neck Exhaust Roof Vent.

  6. Anonymous (verified customer)

    • Daysia W (store manager)

      Thanks for the 5-star review on the Goose Neck Exhaust Roof Vent!

  7. Bradley sharp (verified customer)

    Unfortunately I ordered the wrong vent, nothing on your end I personally made the mistake and will be returning the product. However quick delivery and perfect packaging we appreciate it!

    • Daysia W (store manager)

      Hi Bradley! Thanks for taking the time to leave us a 5-star review and for sharing your experience with us. We are happy to hear you received your product quickly and in good condition! Please let us know if there is anything we can do to help or if you have any questions.

  8. Rodney W. (verified customer)

    An adequately sized roof vent cap could not be sourced by my builder for months. Roofing Direct sent me two of the exact items needed and they arrived within 4 days after I placed my order.

    • Daysia W (store manager)

      Hi Rodney! Thanks for sharing your feedback and for leaving a 5-star review on the Goose Neck Exhaust Roof Vent. We are thrilled to hear you received your product quickly!

  9. James Staats (verified customer)

    Faster delivery than promised!

    • CP (store manager)

      James, we are happy to hear that you received it faster than promised!

  10. Shawn Smith (verified customer)

    nice vent. does the job

    • CP (store manager)

      Shawn, thank you for the 5 star review! Glad to hear that it is doing it’s job!

  11. Andrew (verified customer)

    Everything arrived as expected and as described in good condition. One exception, flap does not have gasket or foam surround to seal from drafts or dampen sound upon closing. Otherwise, was a quick painless purchase with good communication and an otherwise very quality product.

    • CP (store manager)

      Andrew, thank you for your review on the RDP Goose Neck Exhaust Roof Vent. We appreciate the feedback on the flap.

  12. Kenneth S. (verified customer)

  13. Raymond (verified customer)

    Quick shipping got it quick. Bird screen had fell out when showed up. Wouldn’t have kept many birds out. Was able to modify it and fasten screen in.

    • CP (store manager)

      Raymond, thank you for your review. We are sorry to hear that the screen fell out during transit. Please let us know if there is anything we can help you with!

  14. Ritchie S. (verified customer)

    Good Product! Informative throughout the process

    • CP (store manager)

      Ritchie, we are glad that RDP Goose Neck Exhaust Roof Vent was informative throughout the process! Thank you for taking the time for you review!

  15. Timothy Walker (verified customer)

    It would have been nice if the screen was screwed into the piece. It wants to pop out and im afraid once it s put up it will blow out and i will never know it.

    • CL (store manager)

      Hi Timothy, the screen can fall out due to the shaking of the box during transit. It is fairly easy to reinstall and should not come out again under normal use. Please let us know if you need any help getting it put back in.

Add a review

Your email address will not be published. Required fields are marked *

Questions & Answers

Product Question + Answer

    On the 10" unit, what are the specific dimensions of the outlet and overall height? I'm working in a tight area - Thanks!
  1. 0 votes
    Q On the 10" unit, what are the specific dimensions of the outlet and overall height? I'm working i...... Read more
    Asked on September 17, 2022 6:03 am
    A

    The RDP Goose Neck Exhaust Roof Vent in 10" is about 22" in overall height and has an extension measuring 3" long.

  2. How is this unit constructed? Are the joints made water tight with sealant? or is it soldered connections.
  3. 0 votes
    Q How is this unit constructed? Are the joints made water tight with sealant? or is it soldered con...... Read more
    Asked on August 31, 2022 7:29 pm
    A

    The RDP Goose Neck Exhaust Roof Vent is jointed using clinch points and rivets. No additional caulking or sealant is needed for it to be watertight.

  4. I need a 10 inch 1200 CFM vent for my ranger hood to go on a 12/12 pitch roof
  5. 0 votes
    Q I need a 10 inch 1200 CFM vent for my ranger hood to go on a 12/12 pitch roof
    Asked on June 21, 2022 12:19 pm
    A

    The RDP Goose Neck Exhaust Roof Vent does not have official ratings, but the 10" can comfortably handle around 800 CFMs. 1200 CFMs would be exceeding the recommended amount by too much.

  6. I need a 1000 cfm roof vent that fits a 8” pipe. Does your company have one that size
  7. 0 votes
    Q I need a 1000 cfm roof vent that fits a 8” pipe. Does your company have one that size
    Asked on April 27, 2022 7:43 pm
    A

    Unfortunately, the 8" are only recommended for use of up to 800 CFMs.

  8. Can I get this with out damper?and a round slopped base?
  9. 0 votes
    Q Can I get this with out damper?and a round slopped base?
    Asked on April 13, 2022 3:59 pm
    A

    Unfortunately, we are not able to make custom goose neck exhaust vents.

  10. Will the 8in handle 850CFM range hood?
  11. 0 votes
    Q Will the 8in handle 850CFM range hood?
    Asked on January 30, 2022 12:52 am
    A

    The RDP Goose Neck Exhaust Roof Vent - 8 inch, can safely be used with up to 800 CFMs. We recommend going one size up to the 10 inch model, which can handle up to 1000 CFMs.

  12. If I order the goose neck with the bottom extension, is that extension retractable. Thanks.
  13. 0 votes
    Q If I order the goose neck with the bottom extension, is that extension retractable. Thanks.
    Asked on October 26, 2021 8:12 am
    A

    No, the extension on this vent is non-retractable.

  14. I have this vent installed and need to connect 10" diameter vent piping to it. Do you have a transition piece to go from the bottom of this vent to a 10" diameter vent pipe?
  15. 0 votes
    Q I have this vent installed and need to connect 10" diameter vent piping to it. Do you have a tran...... Read more
    Asked on October 18, 2021 6:54 am
    A

    Unfortunately, we do not carry a transition piece for this vent. Your piping can run directly into the bottom of the vent.

  16. Hi, will this cap handle 1200 CFM ? If not which one would you reccomend ? will it work on a pitched roof 3 1/2
  17. 0 votes
    Q Hi, will this cap handle 1200 CFM ? If not which one would you reccomend ? will it work on a pit...... Read more
    Asked on September 7, 2021 5:43 am
    A

    This cap can handle 1200 CFM's as long as you choose the 10" option. These vents work on roof pitches ranging from 3/12 to 8/12.

Related Products

Product Summary

The RDP Goose Neck Exhaust Roof Vent is designed to use with bathroom or kitchen exhaust venting systems. This roof mounted vent comes with a damper to prevent back draft and with an insect screen, and with a 3″ stem for flex pipe connections. Quality constructed in 28 gauge Galvanized steel. The RDP Goose Neck Exhaust Roof Vent comes in the following sizes: 4 inch, 5 inch, 6 inch, 8 inch and 10 inch. This model does not come with an extension. This product is also available with the bottom extension here. This vent is not intended for roof top dryer termination.

RoofingDirect.com offers an excellent selection of exhaust vents made of high quality materials for your next job. Our team has decades of industry experience and is ready to serve you. Please contact us, and we will be happy to answer any questions.

Features + Benefits

  • Designed to use with bathroom or kitchen exhaust venting systems
  • Quality constructed in 28 gauge Galvanized steel
  • Comes with a damper to prevent back draft and with an insect screen

Item #
RDP-GN
Brand
Weight
3 lbs
Material
28 Gauge Galvanized Steel

15 reviews for RDP Goose Neck Exhaust Roof Vent

  1. Scott Jonello (verified customer)

    Great sturdy product would recommend this company to family and friends

    • AM (store manager)

      Hi Scott, Thanks for the great feedback. We appreciate that as we are a family owned company. We appreciate your business.

  2. David Harness (verified customer)

    Product arrived quickly and was well packaged. I didn’t receive any shipping confirmation or arrival date. Would have been nice to plan install.

    • AM (store manager)

      Hi David, we apologize you did not receive the order confirmation or tracking emails. These are automatically generated and sometimes can end up in spam folders. Thanks again for the order, we appreciate your business.

  3. Michael Bailey (verified customer)

    Quick delivery and exact product I needed

    • CL (store manager)

      Sounds like a perfect match. Thanks for shopping at roofing direct!

  4. Aaron M. (verified customer)

    Well built, looks good. The right product for our new 900 cfm kitchen hood with 8 inch vent pipe.

    • CL (store manager)

      Thanks for reviewing the Goose Neck Exhaust Vent!

  5. Reginaldo Peixe (verified customer)

    • Daysia W (store manager)

      Hi Reginaldo! Thanks for taking the time to review the Goose Neck Exhaust Roof Vent.

  6. Anonymous (verified customer)

    • Daysia W (store manager)

      Thanks for the 5-star review on the Goose Neck Exhaust Roof Vent!

  7. Bradley sharp (verified customer)

    Unfortunately I ordered the wrong vent, nothing on your end I personally made the mistake and will be returning the product. However quick delivery and perfect packaging we appreciate it!

    • Daysia W (store manager)

      Hi Bradley! Thanks for taking the time to leave us a 5-star review and for sharing your experience with us. We are happy to hear you received your product quickly and in good condition! Please let us know if there is anything we can do to help or if you have any questions.

  8. Rodney W. (verified customer)

    An adequately sized roof vent cap could not be sourced by my builder for months. Roofing Direct sent me two of the exact items needed and they arrived within 4 days after I placed my order.

    • Daysia W (store manager)

      Hi Rodney! Thanks for sharing your feedback and for leaving a 5-star review on the Goose Neck Exhaust Roof Vent. We are thrilled to hear you received your product quickly!

  9. James Staats (verified customer)

    Faster delivery than promised!

    • CP (store manager)

      James, we are happy to hear that you received it faster than promised!

  10. Shawn Smith (verified customer)

    nice vent. does the job

    • CP (store manager)

      Shawn, thank you for the 5 star review! Glad to hear that it is doing it’s job!

  11. Andrew (verified customer)

    Everything arrived as expected and as described in good condition. One exception, flap does not have gasket or foam surround to seal from drafts or dampen sound upon closing. Otherwise, was a quick painless purchase with good communication and an otherwise very quality product.

    • CP (store manager)

      Andrew, thank you for your review on the RDP Goose Neck Exhaust Roof Vent. We appreciate the feedback on the flap.

  12. Kenneth S. (verified customer)

  13. Raymond (verified customer)

    Quick shipping got it quick. Bird screen had fell out when showed up. Wouldn’t have kept many birds out. Was able to modify it and fasten screen in.

    • CP (store manager)

      Raymond, thank you for your review. We are sorry to hear that the screen fell out during transit. Please let us know if there is anything we can help you with!

  14. Ritchie S. (verified customer)

    Good Product! Informative throughout the process

    • CP (store manager)

      Ritchie, we are glad that RDP Goose Neck Exhaust Roof Vent was informative throughout the process! Thank you for taking the time for you review!

  15. Timothy Walker (verified customer)

    It would have been nice if the screen was screwed into the piece. It wants to pop out and im afraid once it s put up it will blow out and i will never know it.

    • CL (store manager)

      Hi Timothy, the screen can fall out due to the shaking of the box during transit. It is fairly easy to reinstall and should not come out again under normal use. Please let us know if you need any help getting it put back in.

Add a review

Your email address will not be published. Required fields are marked *

Product Question + Answer

    On the 10" unit, what are the specific dimensions of the outlet and overall height? I'm working in a tight area - Thanks!
  1. 0 votes
    Q On the 10" unit, what are the specific dimensions of the outlet and overall height? I'm working i...... Read more
    Asked on September 17, 2022 6:03 am
    A

    The RDP Goose Neck Exhaust Roof Vent in 10" is about 22" in overall height and has an extension measuring 3" long.

  2. How is this unit constructed? Are the joints made water tight with sealant? or is it soldered connections.
  3. 0 votes
    Q How is this unit constructed? Are the joints made water tight with sealant? or is it soldered con...... Read more
    Asked on August 31, 2022 7:29 pm
    A

    The RDP Goose Neck Exhaust Roof Vent is jointed using clinch points and rivets. No additional caulking or sealant is needed for it to be watertight.

  4. I need a 10 inch 1200 CFM vent for my ranger hood to go on a 12/12 pitch roof
  5. 0 votes
    Q I need a 10 inch 1200 CFM vent for my ranger hood to go on a 12/12 pitch roof
    Asked on June 21, 2022 12:19 pm
    A

    The RDP Goose Neck Exhaust Roof Vent does not have official ratings, but the 10" can comfortably handle around 800 CFMs. 1200 CFMs would be exceeding the recommended amount by too much.

  6. I need a 1000 cfm roof vent that fits a 8” pipe. Does your company have one that size
  7. 0 votes
    Q I need a 1000 cfm roof vent that fits a 8” pipe. Does your company have one that size
    Asked on April 27, 2022 7:43 pm
    A

    Unfortunately, the 8" are only recommended for use of up to 800 CFMs.

  8. Can I get this with out damper?and a round slopped base?
  9. 0 votes
    Q Can I get this with out damper?and a round slopped base?
    Asked on April 13, 2022 3:59 pm
    A

    Unfortunately, we are not able to make custom goose neck exhaust vents.

  10. Will the 8in handle 850CFM range hood?
  11. 0 votes
    Q Will the 8in handle 850CFM range hood?
    Asked on January 30, 2022 12:52 am
    A

    The RDP Goose Neck Exhaust Roof Vent - 8 inch, can safely be used with up to 800 CFMs. We recommend going one size up to the 10 inch model, which can handle up to 1000 CFMs.

  12. If I order the goose neck with the bottom extension, is that extension retractable. Thanks.
  13. 0 votes
    Q If I order the goose neck with the bottom extension, is that extension retractable. Thanks.
    Asked on October 26, 2021 8:12 am
    A

    No, the extension on this vent is non-retractable.

  14. I have this vent installed and need to connect 10" diameter vent piping to it. Do you have a transition piece to go from the bottom of this vent to a 10" diameter vent pipe?
  15. 0 votes
    Q I have this vent installed and need to connect 10" diameter vent piping to it. Do you have a tran...... Read more
    Asked on October 18, 2021 6:54 am
    A

    Unfortunately, we do not carry a transition piece for this vent. Your piping can run directly into the bottom of the vent.

  16. Hi, will this cap handle 1200 CFM ? If not which one would you reccomend ? will it work on a pitched roof 3 1/2
  17. 0 votes
    Q Hi, will this cap handle 1200 CFM ? If not which one would you reccomend ? will it work on a pit...... Read more
    Asked on September 7, 2021 5:43 am
    A

    This cap can handle 1200 CFM's as long as you choose the 10" option. These vents work on roof pitches ranging from 3/12 to 8/12.

Related Products

Scroll to Top

Thank You!

Your registration was successful. You have received 10 points to use on your first order.